Technical Details
Dimensions
Moments
Dimensions
H | Total height | 55 | mm |
H1 | 6.5 | mm | |
N | 18 | mm | |
W | Block width | 70 | mm |
B | 50 | mm | |
B1 | 10 | mm | |
C | 50 | mm | |
L1 | 79 | mm | |
L | Block length | 124 | mm |
K1 | 22.5 | mm | |
K2 | 10 | mm | |
G | 12 | mm | |
M | M8 | ||
l | 12 | mm | |
T | 12 | mm | |
H2 | 16 | mm | |
H3 | 19.6 | mm | |
Mass | 1.57 | kg |
Load ratings and torques
Cdyn | Dynamic load rating | 57.900 | N |
C0 | Static load rating | 105.200 | N |
M0X | Static moment | 2.170 | Nm |
M0Y | Static moment | 1.440 | Nm |
M0Z | Static moment | 1.440 | Nm |
Details
Load ratings
Static load rating C0
If a linear guideway system is subjected to excessive loads or impacts during movement or at a standstill, localised permanent deformation occurs between the track and balls. As soon as this permanent deformation exceeds a certain level, it affects smooth operation of the guideway. According to its basic definition, the static load rating corresponds to a static load that causes permanent deformation of 0.0001 × ball diameter at the contact point that is loaded the most. The values are given in the tables for each linear guideway system. Using these tables, the designer can select a suitable linear guideway system. The maximum static load to which a linear guideway system is subjected must not exceed the static load rating.
Permissible static moment M0
The permissible static moment is the moment which, in a defined direction and size, corresponds to the maximum possible load on the moving parts by the basic static load rating. The permissible static moment is defined for linear motion systems for three directions: MX, MY and MZ.
Lubrication
Long-time lubrication unit E2
The long-time lubrication unit considerably increases lubrication intervals. Depending on the application and ambient conditions, it can achieve lifetime lubrication. It also considerably reduces lubricant consumption, as only the required quantity of lubricant is applied. The compact construction and special design allows the block to be fitted in any position without impairing the lubrication function. The long-time lubrication unit can be used at ambient temperatures of -10°C to +60°C.